1、Features

   1). Equipped with high-speed, small-sized, multifunctional MCU.

   2). Full protection feature including low-voltage protection, over-heat protection, signal lost

        protection, safe power on protection.

   3). Excellent startup performance, great throttle linear and quick throttle response.

   4). Max speed: 240,000 RPM (2 poles), 80,000 RPM (6 poles), 40,000 RPM (12 poles).

   5). The parameters of ESC can be configured via transmitter .

   6). Throttle range can be configured to be compatible with different receivers.

2、Specification

   · Input voltage: 2.8V -4.2V (support 1 lithium batteries)

   · Continue current: 3A

   · Burst current: 4A (within 10 seconds) 

   · BEC output: NO

   · Size( lengthX width X high): 11x13x8 mm

   · Weight: 0.7 g

3、Parameter

   1).BrakeType: Off,Soft brake and Hard brake. default is Off (brake disable). Soft brake: less

         forceful and brake time is longer. Hard brake:more forceful and brake time is shorter.

   2).AdvanceT(Timing Mode): Low, Middle and High, default is Middle. Low advance timing is

         recommended for high inductance and low KV motors. High advance timing is recommended for low

         inductance and high KV motors, e.g. high KV outrunner motors. For some high KV motors, if it

         shakes while rotating in high speed, the “High” timing mode is recommended.

   3).Start: Fast, Soft and Very Soft. default is Very Soft. Fast start is recommended for low

          inductance and low start loading motors, Very Soft start is recommended for high inductance

          and high start loading motors.

   4).OffType(Cutoff Mode,Low Voltage Protection Mode): Reduce power and Cutoff output power

          for selecting,default is Reduce the output power gradually to 50% of the current power. 

   5).Cutoff  threshold: 2.8V, 3.0V, 3.1V. default is 2.8V.

          Note : The detailed explanation see "User Manual of XP-3A."

 